HOSPITAL ÁNGELES METROPOLITANO

Tlacotalpan 59, Roma Sur, Cuauhtémoc, 06760 Ciudad de México, CDMX, TORRE DIAMANTE CONSULTORIO 730

5564 2870 / 5564 6000 / FAX 5264 7941

Lunes, Miércoles y Jueves: 19:00 - 20:30

El análisis basado en modelos en radiostereometría es adecuado para ensayos clínicos sobre el componente glenoideo de la artroplastia reversa total de hombro.

Este estudio tiene como objetivo validar el análisis radiostereométrico basado en modelos (RSA) en el componente glenoideo de la artroplastia total de hombro invertida.  La RSA basada en modelos en el componente glenoideo de la artroplastia reversa  total de hombro tiene una alta precisión y precisión, comparable a los resultados de RSA en caderas y rodillas. El posicionamiento del paciente es vital para obtener resultados adecuados. Encontramos que la ingeniería reversa era el método más confiable y recomendamos la ingeniería reversa como el método de elección para la investigación clínica adicional de RSA del componente glenoideo de la artroplastia reversa total de hombro.

<span title=”KEYWORDS:

“>PALABRAS CLAVE:

Análisis radiostereométrico (RSA); exactitud; componente glenoideo; modelo de RSA; estudio fantasma; precisión; artroplastia

 

Fuente

https://www.ncbi.nlm.nih.gov/pubmed/30035319

https://onlinelibrary.wiley.com/doi/abs/10.1002/jor.24111

Fraser AN1,2, Tsukanaka M2,3, Fjalestad T1, Madsen JE1,2, Röhrl SM1.

2018 Jul 23. doi: 10.1002/jor.24111. [Epub ahead of print]

© 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

PMID: 30035319 DOI: 10.1002/jor.24111

Los componentes glenoideos convertibles facilitan las revisiones de la artroplastia de hombro inversa más fácil: revisión retrospectiva de 13 casos

Convertible Glenoid Components Facilitate Revisions to Reverse Shoulder Arthroplasty Easier: Retrospective Review of 13 Cases

 

Fuente

Este artículo es publicado originalmente en:

 

https://www.ncbi.nlm.nih.gov/pubmed/29494717

https://www.amjorthopedics.com/article/convertible-glenoid-components-facilitate-revisions-reverse-shoulder-arthroplasty-easier

 

De:

Valenti P1Katz DKany JWerthel JD.

 2018 Feb;47(2). doi: 10.12788/ajo.2018.0008.

 

Todos los derechos reservados para:

 

Copyright ©2018 Frontline Medical Communications Inc. Parsippany; NJ, USA. All rights reserved.

 

Abstract

Removal of a cemented glenoid component often leads to massive glenoid bone loss, which makes it difficult to implant a new glenoid baseplate. The purpose of this study was to demonstrate the feasibility of revisions with a completely convertible system and to report clinical and radiographic results of a retrospective review of 13 cases. Between 2003 and 2011, 104 primary total shoulder arthroplasties (TSAs) were performed with an uncemented glenoid component in our group. Of these patients, 13 (average age, 64 years) were revised to reverse shoulder arthroplasty (RSA) using a modular convertible platform system and were included in this study. Average follow-up after revision was 22 months. Outcome measures included pain, range of motion, Constant-Murley scores, Simple Shoulder Tests, and subjective shoulder values. Active flexion increased significantly from a mean of 93° (range, 30°-120°) to 138° (range, 95°-170°) (P = 0.021), and active external rotation increased significantly from 8° (range, -20°-15°) to 25° (range, -10°-60°). Mean pain scores significantly improved from 4.2 to 13.3 points. The mean Constant Scores improved from 21 (range, 18-32) to 63 (range, 43-90). Subjectively, 12 patients rated their shoulder as better or much better than preoperatively. This retrospective study shows that a complete convertible system facilitates conversion of TSAs to RSAs with excellent pain relief and a significant improvement in shoulder function.}

 

 

Resumen

 

La extracción de un componente glenoideo cementado a menudo conduce a la pérdida masiva de hueso glenoideo, lo que dificulta la implantación de una nueva placa base glenoidea. El objetivo de este estudio fue demostrar la viabilidad de las revisiones con un sistema completamente convertible e informar los resultados clínicos y radiográficos de una revisión retrospectiva de 13 casos. Entre 2003 y 2011, se realizaron 104 artroplastias totales de hombro primarias (TSA) con un componente glenoideo no cementado en nuestro grupo. De estos pacientes, 13 (edad promedio, 64 años) fueron revisados ​​para artroplastia de hombro invertida (RSA) usando un sistema modular de plataforma convertible y se incluyeron en este estudio. El seguimiento promedio después de la revisión fue de 22 meses. Las medidas de resultado incluyeron dolor, rango de movimiento, puntuaciones de Constant-Murley, pruebas simples de hombro y valores subjetivos de hombro. La flexión activa aumentó significativamente desde una media de 93 ° (rango, 30 ° -120 °) a 138 ° (rango, 95 ° -170 °) (P = 0.021), y la rotación externa activa aumentó significativamente desde 8 ° (rango, – 20 ° -15 °) a 25 ° (rango, -10 ° -60 °). Las puntuaciones medias de dolor mejoraron significativamente de 4.2 a 13.3 puntos. La puntuación constante promedio mejoró de 21 (rango, 18-32) a 63 (rango, 43-90). Subjetivamente, 12 pacientes calificaron su hombro como mejor o mucho mejor que en el preoperatorio. Este estudio retrospectivo muestra que un sistema convertible completo facilita la conversión de TSA a RSA con un excelente alivio del dolor y una mejora significativa en la función del hombro.

PMID:  29494717